background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/01/21

Message Overview:

Message  Name:

CH A&B FAULT

Message  Code:

B3-006457

Associated CAS:

AIR COND FAULT
(Advisory)

Reporting LRU: CKPT T SEL PNL
System Description: 21-61-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

Both channels of the COCKPIT TEMPERATURE SELECTOR located on the Bleed/Air Conditioning Panel are detected.

Possible Causes:

  • Cockpit Temperature Selector (CKSEL) (R02)
  • Air Cond/Bleed Control Panel (PL17)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 1
  2. Fault Logged = AIR,TAXI
  3. Status = FAILED/WIRING
  4. {Term Definitions}

    1. IAS1A-56 XX 353 00 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 353A: 22; COCKPIT TEMP SELECTOR A
    2. IAS2A-61 XX 353 10 EXCT XXXX-XXXX XXTX-XXXX XXXX-XXXX 353A: 22; COCKPIT TEMP SELECTOR B

Quick Links:

Removal of the Integrated Air System (IAS) Controller AMM 21-31-01-000-801
Installation of the Integrated Air System (IAS) Controller AMM 21-31-01-400-801
Removal of the Bleed-Air Control Panel AMM 36-11-57-000-801
Installation of the Bleed-Air Control Panel AMM 36-11-57-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Check for selector failure.