02/02/21
Message Overview:
Messge Description:
The DIFFERENTIAL PRESSURE SENSOR 1 is detected failed. No signal is received or the signal is out of range. Check the sensor or the wiring to the sensor and the IASC # 1.
Possible Causes:
- Differential Pressure Sensor 1 (MT23)
- Integrated Air System Controller (IASC #1) (A55)
- Junction Box 1 (JB1)
- Junction Box 3 (JB3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IASC) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IASC) Controller | AMM 21-31-01-400-801 |
| Removal of the Differential Pressure Sensor | AMM 21-51-03-000-801 |
| Installation of the Differential Pressure Sensor | AMM 21-51-03-400-801 |
| Removal of the Junction Boxes | AMM 24-63-01-000-802 |
| Installation of the Junction Boxes | AMM 24-63-01-400-802 |
| Operational Test of the Bleed Air System | AMM 36-11-00-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the L WING / BLD LK circuit breakers CB1-E10.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap the Differential Pressure Sensor 1 with the Differential Pressure Sensor 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the Differential Pressure Sensor 1 (MT23) and the IASC 1. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap the IASC 1 with the IASC 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the Differential Pressure Sensor 1 (MT23) and the JB1. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of JB1. Replace JB1 as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between JB1 and JB3. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of JB3. Replace JB3 as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of JB3 and the Circuit Breaker CB1-E10. Repair as required.
- Do close out.