Message Overview:
Message Name:
DISCRETE DISABLE FAIL
Message Code:
B3-006707
Associated CAS:
| Reporting LRU: | FLOW CTRL VLV2 |
| System Description: | 21-61-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
The discrete disable input of the FLOW CONTROL VALVE 2 is detected failed.
Possible Causes:
- Integrated Air System Controller (IASC) (A55)
- Bleed/Air Conditioning Panel (MPE04)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 3
- Fault Logged = AIR,TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- IAS2A-40 XX 352 10 EXCT XXXX-XXXX XXXX-XXXT XXXX-XXXX 352A: 17; R FLOW CTRL VLV DISABLE
Quick Links:
| Installation of Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Removal of Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Removal of Flow Control Valve | AMM 21-51-09-000-801 |
| Deactivation of the Flow Control Valve | AMM 21-51-09-040-801 |
| Installation of Flow Control Valve | AMM 21-51-09-400-801 |
| Activation of the Flow Control Valve | AMM 21-51-09-440-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- The discrete disable input of the FLOW CONTROL VALVE 2 is detected failed.
- Check wiring between the IASC-2 and the Bleed/Air Conditioning Panel.