02/02/21
Message Overview:
Message Description:
The internal pressure sensor of the IASC-1 is detected out of range or disagrees with the Air Data Computer data and the IASC-2 sensor.
Possible Causes:
- Integrated Air System Controller (IASC-1) (A55)
- Integrated Air System Controller (IASC-2) (A56) Sensor
- Air Data Computer (ADC) (A1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Cabin Pressure Control System | AMM 21-31-00-710-801 |
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check the #1 IAS controller circuit breaker CB1 D14 & CB1 E10, reset and re-check MDC for the bus fault.
- Suspect the #1 Integrated Air System Controller is at fault. Cross compare the #1 IAS controller channel A cabin pressure sensor status to ambient or test pressures. Access the pressurization raw data through the MDC IASC LRU TEST page, further details are covered in section (21-23-00).
- Perform the operational test of the cabin pressure control system.
- Suspect the #1 IAS controller, remove and replace Integrated Air System (IAS) Controller.
- Operational test of the Integrated Air System (IAS) Controller.