Message Overview:
Message Description:
The internal pressure sensor of the IASC-2 is detected out of range or disagrees with the Air Data Computer data and the IASC-1 sensor is detected.
Possible Causes:
- Integrated Air System Controller (IASC-2) (A56)
- Integrated Air System Controller (IASC-1) (A55)
- Air Data Computer (ADC) (A1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check the #2 IAS controller circuit breaker CB2 D14 & CB2 E10, reset and re-check MDC for the bus fault.
- Check the air data computer altitude on the PFDs for reasonable indication. If the Air Data Computer indication appears to be incorrect for the conditions (maintenance should see field elevation) then troubleshoot the Air Data Computer system.
- Compared the #1 IASC LRU testing raw data (Description 21-23-00), PRESS/TEMP SENSOR STATUS page to the #2 IASC. The Cabin pressure indications should match and be equivalent to actual aircraft conditions, maintenance should see ambient pressure indications. Replace either IASC if they do not match these conditions.
- Suspect the #2 IAS controller, remove and replace Integrated Air System (IAS) Controller.
- Operational test of the Integrated Air System (IAS) Controller.