08/09/21
Message Overview:
Message Name:
CH B FAULT
Message Code:
B3-007332
Associated CAS:
| Reporting LRU: | PK DISCH T SNSR |
| System Description: | 21-61-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
The channel B of the PACK DISCHARGE TEMPERATURE SENSOR is detected failed.
Possible Causes:
- Pack Discharge Temperature Sensor (MT33)
- Integrated Air System Controller (IASC1) (A55)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 3
- Fault Logged = AIR, TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- IAS1A-45 XX 352 01 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 352B: 16; PACK DISCHRG TEMP SNSR
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Removal of the Pack Discharge Temperature-Sensor | AMM 21-52-37-000-801 |
| Installation of the Pack Discharge Temperature-Sensor | AMM 21-52-37-400-801 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- The channel B of the PACK DISCHARGE TEMPERATURE SENSOR is detected failed. Check the sensor or the wiring to the sensor and the IASC #1.