02/03/21
Message Overview:
Message Name:
DISAGREE / VALVE CLOSED
Message Code:
B3-007663
Associated CAS:
| Reporting LRU: | PRECOOLER XVALVE |
| System Description: | 21-61-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
The PRECOOLER CROSS VALVE is detected failed in closed position.
Possible Causes:
- Air Conditioning Panel (PL17)
- Precooler Cross-Over Valve (MPE11)
- Precooler Cross Valve Relay
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 1
- Comp Id = MPE11
- Fault Logged = AIR, TAXI
- Status = FAILED/WIRING
- Message Type = Fault Message
- {Term Definitions}
- IAS1A-33 XX 352 00 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 352A: 13; PRECOOLER XBLEED VLV FA
- IAS2A-37 XX 352 10 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 352A: 13; PRECOOLER XBLEED VLV FA
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Precooler Cross-Over Valve | AMM 21-61-07-000-801 |
| Installation of the Precooler Cross-Over Valve | AMM 21-61-07-400-801 |
| Removal of the Bleed-Air Control Panel | AMM 36-11-57-000-801 |
| Installation of the Bleed-Air Control Panel | AMM 36-11-57-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- The PRECOOLER CROSS VALVE is detected failed in closed position. Check wiring. Suspect Air Conditioning panel or Precooler Cross Valve or Precooler Cross Valve Relay.