02/03/21
Message Overview:
Message Description:
No left FGC installed in the aircraft.
Possible Causes:
- Left IAPS Power Supply Card 1 (PWR-3000) (A4-PWR)
- Flight Guidance Computer 1 (FGC) (A4-FGC)
- Input/Output Concentrator 1 (IOC) (A4-IOC)
- IAPS Card Cage (A4)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: If this is the only MDC fault and there is no other cockpit indications or messages, the priority of possible LRU failure will be FGC, and IAPS CARD CAGE.
Quick Links:
| Removal of Flight Guidance Computer (FGC) | AMM 22-11-01-000-801 |
| Installation of Flight Guidance Computer (FGC) | AMM 22-11-01-400-801 |
| Removal of Integrated Avionics Processor System (IAPS) Card Cage | AMM 31-45-01-000-801 |
| Installation of Integrated Avionics Processor System (IAPS) Card Cage | AMM 31-45-01-400-801 |
| Removal of Input/Output Concentrator (IOC) | AMM 31-45-05-000-801 |
| Installation of Input/Output Concentrator (IOC) | AMM 31-45-05-400-801 |
| Removal of Integrated Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-000-801 |
| Installation of Integrated Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-400-801 |
Troubleshooting Recommendations:
- Verify L ESS BUS is powered and CB1-B6 is in.
- Clear fault messages related to Configuration Strapping Unit (CSU)1 or (CSU)2.
- Swap PWR supplies.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap FGC cards.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace IAPS card cage.
- Do close out.