02/16/21
Message Overview:
Message Description:
L-IOC-2 bus is reported missing by L-TDR and R-TDR.
Possible Causes:
- Left Input/Output Concentrator Unit (IOC 1) (A4IOC1)
- Junction Box 4 (JB4)
- Left Air Traffic Control (ATC) Transponder (A31)
- Right Air Traffic Control (ATC) Transponder (A30)
- Left File Server Unit (FSU 1) (A221)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Boxes | AMM 24-63-01-000-802 |
| Installation of the Junction Boxes | AMM 24-63-01-400-802 |
| Removal of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset L IAPS (CB1-B6) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IOCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do a wiring check of the ARINC 429 data bus L-IOC-2 from IAPS connector A4P3, through Junction Box 4, to ATC Transponder 1 connector A31P2, to ATC Transponder 2 connector A30P2 and FSU 1 connector A221P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRUs connected to this data bus might cause this failure.
- Swap ATC Transponders.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace FSU 1.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap FSUs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace ICC.
- Do close out.