Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/18/21

Message Overview:

Message Name:

NO OUTPUT

Message Code:

B3-006465

Associated CAS:

None

Reporting LRU: CPE 2 AUDIO
System Description: 23-00-00
Schematic Diagram: 23-51-00
Wiring Diagram: 23-51-03
23-51-06
23-51-09
23-51-11

Message Description:

R-CPE bus data not received at R-RIU and L-RIU.

Possible Causes:

  • Right Control Panel Electronics (CPE 2) (A168)
  • Junction Box 2 (JB2)
  • Right Audio Control Panel (ACP 2) (PL2)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Audio Control Panel AMM 23-51-05-000-801
Installation of the Audio Control Panel AMM 23-51-05-400-801
Removal of the Control Panel Electronic (CPE) AMM 23-51-09-000-801
Installation of the Control Panel Electronic (CPE) AMM 23-51-09-400-801
Removal of the Secondary Power Center (SPC) AMM 24-62-01-000-801
Installation of the Secondary Power Center (SPC) AMM 24-62-01-400-801
Removal of the Junction Box JB2 AMM 24-63-05-000-803
Installation of the Junction Box JB2 AMM 24-63-05-400-803
Removal of the Cockpit Circuit-Breaker Panel (CCBP) AMM 24-65-01-000-801
Installation of the Cockpit Circuit-Breaker Panel (CCBP) AMM 24-65-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Simultaneously reset R AUDIO PWR 1 Circuit Breaker CB2-B1 and R AUDIO PWR 2 Circuit Breaker CB3-F4. Is the fault message still present?
    1. If YES, continue with next step.
    2. If NO, do close out.

  2. Swap right CPE (A168) with left CPE (A167). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace defective CPE.

  3. Do wiring check between the right CPE (A168) and the Junction Box 2 (JB2) for the following wires:

    From To Result
    Conn. A168P1 - 3 Aircraft Ground
    Conn. A168P1 - 8 Aircraft Ground
    Conn. A168P1 - 1 Conn. JB2BP1 - 10H

    1. If the check is satisfactory, go to next step.
    2. If the check is not satisfactory, repair defective wiring or replace JB2.

  4. Do wiring check between the Junction Box 2 (JB2), the Circuit Breaker Panel 2, the left Secondary Power Center (A37) and the right Audio Control Panel (PL2) for the following wires:

    From To Result Note
    Conn. JB2AP1 - 6A Conn. A37P3 - 18 Respect diode CR47 polarity.
    Conn. JB2AP1 - 10K Conn. CBP2J3 - 11 Respect diode CR47 polarity.
    Conn. JB2AP1 - 10J Conn. PL2P1 - A

    1. If the check is satisfactory, go to next step.
    2. If the check is not satisfactory, repair defective wiring.
      NOTE: A short circuit on one of these wire or internally to the Audio Control Panel 2 will cause this fault message.

  5. Replace the right Audio Control Panel (PL2).
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.