02/24/21
Message Overview:
Message Description:
Failure or problem is reported in the right HF fiber optic control.
- Fiber optic control bus fault (Label 351 - Bit 25)
Possible Causes:
- Right HF Transceiver (HF) 2 (A62)
- Right HF Antenna Coupler (CP6)
- Associated Wiring (Fiber Optic Cable)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the HF Transceiver | AMM 23-12-01-000-801 |
| Installation of the HF Transceiver | AMM 23-12-01-400-801 |
| Removal of the HF Antenna Coupler | AMM 23-12-09-000-801 |
| Installation of the HF Antenna Coupler | AMM 23-12-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
| Standard Practices - Fiber Optics | SPM 20-51-00-02 |
Troubleshooting Recommendations:
- Reset HF 2 Circuit Breaker CB2-B3 and HF 2 PWR Circuit Breaker CB6-A1. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap right HF Transceiver (A62) with Left HF Transceiver (A61). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective HF Transceiver.
- Swap right HF Antenna Coupler (CP6) with Left HF Antenna Coupler (CP5). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective HF Antenna Coupler.
- Inspect / check Optical Fiber Cables integrity as per SPM 20-51-00-02. Repair/Replace as required.
From To Result Conn. A62P2 Conn. CP6P3 Conn. A62P3 Conn. CP6P2 - Do close out.