02/24/21
Message Overview:
Message Description:
SATCOM data is not being received by L IOC, L CDU and RIU-datalink.
Possible Causes:
- SATCOM Satellite Data Unit (SDU)
- Circuit breaker
- Current Thermal Sensor (RT06)
- Remote-Control Circuit Breaker (RCCB) Contactors (K144)
- Right DC Power Center (R DCPC) (A36)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
Troubleshooting Recommendations:
- Reset SATCOM (CB4-D2) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Confirm presence of the 28 VDC and grounds at SDU connector A82CP1.
- If 28 VDC and grounds are present, go to step 9.
- If 28 VDC is not present, go to next step 4.
- If grounds are not present, continue with next step.
- Repair/replace, as required, the wiring and/or the ground stud.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the wiring check between R DCPC connector A36P4 and SDU connector A82CP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Confirm proper operation of the SATCOM (CB4-D2) control circuit breaker by measuring the presence of a ground at R DCPC connector A36AP4 - Pin 8. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap Remote-Control Circuit Breaker (RCCB) Contactors (K144 with K108).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap Current Thermal Sensors (RT06 with RT04).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace R DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SDU.
- Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.
| Removal of the SATCOM Satellite Data Unit (SDU) | AMM 23-15-01-000-801 |
| Installation of the SATCOM Satellite Data Unit (SDU) | AMM 23-15-01-400-801 |
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Removal of the Current Thermal Sensor | AMM 24-61-51-000-801 |
| Installation of the Current Thermal Sensor | AMM 24-61-51-400-801 |
| Removal of the Remote Control Circuit Breaker (RCCB) Contactors | AMM 24-61-61-000-801 |
| Installation of the Remote Control Circuit Breaker (RCCB) Contactors | AMM 24-61-61-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |