Message Overview:
Message Description:
The Left Auxiliary/Main Fuse (LAXF1) connecting the Left Main Bus to the Left Auxiliary Bus, located in the Left DCPC, has blown.
Possible Causes:
- Left Auxiliary/Main Fuse (LAXF1) (F5)
- Left DC Power-Center Protection (LPROT) (PCB1)
- Left DC Power Center (L DCPC) (A35)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the Power Center (DCPC) | AMM 24-61-01-400-801 |
| Removal of the DC Power-Center Protection | AMM 24-61-77-000-801 |
| Installation of the DC Power-Center Protection | AMM 24-61-77-400-801 |
| Removal of the DC Power-Center Fuses | AMM 24-61-79-000-801 |
| Installation of the DC Power-Center Fuses | AMM 24-61-79-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Disconnect both batteries and the External DC power.
- Inspect Left DCPC (A35), external and internal, for any signs of burning and any foreign object that could have caused a short circuit.
- If inspection is okay, continue with next step.
- If inspection is not okay, go to step 6.
- Remove, inspect and measure the Left Auxiliary/Main Fuse (F5) located in the Left DCPC (A35). Is the Fuse good?
- If YES, go to step 5.
- If NO, continue with next step.
- Replace the Left Auxiliary/Main Fuse (F5). Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap the Left DC Power-Center Protection (PCB1) with the Right DC Power-Center Protection (PCB2). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective DC Power-Center Protection.
- Replace the Left DCPC (A35).
- Do close out.