Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/25/21

Message Overview:

Message Name:

FAULT

Message Code:

B3-268885

Associated CAS:

None

Reporting LRU: R GEN PMG RLY2
System Description: 24-61-00
Schematic Diagram: None
Wiring Diagram: None

Message Description:

The Right Generator PMG Relay 2 (RGPR2) has failed.

Possible Causes:

  • Right Generator PMG Relay 2 (RGPR2) (K164)
  • Right DC Power-Center Protection (RPROT) (PCB2)
  • Right DC Power Center (RDCPC) (A36)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-24-0024 - Electrical System - Troubleshooting Tips
  • AW300-24-0137 - Y06 Electrical System Upgrade
  • AW300-24-0162 - Service Bulletin 100-24-20 - DC Power Center (DCPC) System - Inspection and Replacement of Internal Fuses in the L/H and R/H DC Power Center (DCPC)

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of the DC Power Center (DCPC) AMM 24-61-01-400-801
Functional Test of the DC Power Center (DCPC) AMM 24-61-01-720-801
Removal of the DC Power-Center Protection AMM 24-61-77-000-801
Installation of the DC Power-Center Protection AMM 24-61-77-400-801
Removal of the DC Power-Center Relays AMM 24-61-81-000-801
Installation of the DC Power-Center Relays AMM 24-61-81-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Swap the Right Generator PMG Relay 2 (K164) with Left Generator PMG Relay 2 (K163). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Generator PMG Relay.

  2. Swap the Right DC Power-Center Protection (PCB2) with the Left DC Power-Center Protection (PCB1). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Right DC Power-Center Protection.

  3. Replace Right DC Power Center (A36).
  4. Do close out.