Message Overview:
Message Description:
The HMDG Line Contactor, located inside the HMDG Power Center, has failed during Maintenance Test.
Possible Causes:
- Hydraulic-Motor Driven Generator Power Center (HMDGPC) (A205)
- Generator Control Unit (GCU) - Emergency (HMDGCU) (A206)
- Remote Date Concentrator (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB100-24-04 - MODIFICATION - EMERGENCY DC-POWER SYSTEM - Installation of the Hydraulic Motor Driven Generator (HMDG) Option (C24-300)
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
|
Quick Links:
| Removal of the Generator Control Unit (GCU) - Emergency | AMM 24-33-09-000-801 |
| Installation of the Generator Control Unit (GCU) - Emergency | AMM 24-33-09-400-801 |
| Removal of the Power Center | AMM 24-33-13-000-801 |
| Installation of the Power Center | AMM 24-33-13-400-801 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do a wiring check of the following wires:
From To Results RDC connector A13FP1 - pin G7 HMDGPC connector A205P1 - pin B Aircraft Ground Stud GS4214 HMDGPC connector A205P1 - pin A HMDG GCU connector A206P1 - pin M HMDGPC connector A205P1 - pin J HMDG GCU connector A206P1 - pin L HMDGPC connector A205P1 - pin K - If wiring check is satisfying, go to next step.
- If wiring check is not satisfying, repair defective wire.
- Replace the HMDG Power Center (A205). Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Generator Control Unit (GCU) - Emergency (A206). Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the Remote Data Concentrator (A13).
- Do close out.