02/25/21
Message Overview:
Message Description:
The Hydraulic-Motor Driven Generator Control Unit has failed during the Maintenance Test.
Possible Causes:
- Generator Control Unit (GCU) - Emergency (HMDG GCU) (A206)
- Hydraulic-Motor Driven Generator (HMDG) (G4)
- Remote Data Concentrator Unit (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB100-24-04 - MODIFICATION - EMERGENCY DC-POWER SYSTEM - Installation of the Hydraulic Motor Driven Generator (HMDG) Option (C24-300)
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
|
Quick Links:
| Removal of the Hydraulic-Motor Driven Generator | AMM 24-33-01-000-801 |
| Installation of the Hydraulic-Motor Driven Generator | AMM 24-33-01-400-801 |
| Removal of the Generator Control Unit (GCU) - Emergency | AMM 24-33-09-000-801 |
| Installation of the Generator Control Unit (GCU) - Emergency | AMM 24-33-09-400-801 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check as per the following table:
From To Results HMDG GCU conn. A206P2 - A HMDG conn. G4P4 - pin 1 HMDG GCU conn. A206P2 - B HMDG conn. G4P4 - pin 2 HMDG GCU conn. A206P2 - K HMDG conn. G4P5 - pin C HMDG GCU conn. A206P2 - Y HMDG conn. G4P5 - pin F HMDG GCU conn. A206P2 - Z Aircraft Ground HMDG GCU conn. A206P1 - D HMDG conn. G4P5 - pin B HMDG GCU conn. A206P1 - C HMDG conn. G4P5 - pin A HMDG GCU conn. A206P1 - R Aircraft Ground HMDG GCU conn. A206P1 - X Aircraft Ground HMDG GCU conn. A206P2 - G RDC conn. A13EP1 - pin 6J HMDG GCU conn. A206P2 - H RDC conn. A13EP1 - pin 6K HMDG GCU conn. A206P1 - P RDC conn. A13FP1 - pin 6H - If the check is not satisfactory, repair/replace the defective wiring.
- If the check is satisfactory, continue with next step.
- Replace the HMDG GCU (A206). Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the HMDG (G4). Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the RDC (A13).
- Do close out.