arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/26/21

Message Overview:

Message Name:

BOTH BRIDGEWIRES OPEN

Message Code:

B3-008154

Associated CAS:

FIREX BTL 2 FAULT
(Advisory)

Reporting LRU: L ENG BTL2 SQUIB
System Description: 26-00-00
Schematic Diagram: 26-21-00
Wiring Diagram: 26-21-09

Message Description:

Both Left Engine Bottle 2 Bridgewires have failed or both wires are open.

Possible Causes:

  • Left Engine Discharge Cartridge (A113) of Fire Bottle No. 2
  • Fire-Detection-and-Extinguishing Control Unit (FIREX CU) (A91)
  • Junction Box 4 (JB4)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

WARNING: OBEY THE LOCAL REGULATIONS WHEN YOU USE EXPLOSIVE DEVICES OR PUT THEM IN STORAGE. DISCARD THE DISCHARGE CARTRIDGES SAFELY AND CORRECTLY. THE DISCHARGE CARTRIDGES CAN FIRE ACCIDENTALLY. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.

WARNING: MAKE SURE THAT THE ELECTRICAL CIRCUITS ARE NOT ENERGIZED WHEN YOU CONNECT THE ELECTRICAL CONNECTOR TO THE DISCHARGE CARTRIDGE. IF THE ELECTRICAL CIRCUITS ARE ENERGIZED, THE DISCHARGE CARTRIDGE CAN FIRE ACCIDENTALLY. THIS CAN CAUSE INJURY TO PERSONS OR DAMAGE TO THE EQUIPMENT.

Quick Links:

Removal of the Junction Box JB3 AMM 24-63-09-000-802
Installation of the Junction Box JB3 AMM 24-63-09-400-802
Removal of the Junction Box JB4 AMM 24-63-13-000-802
Installation of the Junction Box JB4 AMM 24-63-13-400-802
Removal of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit AMM 26-11-01-000-801
Installation of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit AMM 26-11-01-400-801
Removal of the Discharge Cartridge AMM 26-21-05-000-801
Installation of the Discharge Cartridge AMM 26-21-05-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Pull and reset FIREX Control Unit (A91) circuit breakers CB6-A4 and CB5-A3. Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, do close out.

  2. Swap Left Engine Discharge Cartridge (A113) of Fire Bottle no. 2 with one of the 2 other Discharge Cartridge (A114 or A115) of Fire Bottle no. 2. Is the message fault still present?
    1. If YES, continue with next step.
    2. If NO, replace defective Discharge Cartridge.

  3. Do wiring check between Left Engine Discharge Cartridge (A113) of Bottle 2 to FIREX Control Unit (A91), through JB4, for the following wires:

    From To Results
    Conn A113P1 - 1 Conn A91P2 - 26
    Conn A113P1 - 2 Ground
    Conn A113P1 - 3 Conn A91P2 - 26
    Conn A113P1 - 4 Ground

    1. If check is not satisfactory, repair wiring or replace JB4.
    2. If check is satisfactory, continue with next step.

  4. Replace FIREX Control Unit (A91).
  5. Do close out.

21_firex_cu_install60_Lh_dcpc_cb_panel60_lh_cbpnl