Message Overview:
Message Description:
Flap Control Unit (FCU) detected an Asymmetry in the Flap System. Check mechanical driveline (If OB Actuator is disconnected or replaced, Flaps must be rigged).
Possible Causes:
- Mechanical driveline
- Flap Position Sensor (LH) (MPE77)
- Flap Position Sensor (RH) (MPE78)
- Flap Power Unit (FPU) (A123)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0058 - Flap Control Unit - CAS Messages Reset procedure (20501 to 20999)
Forum Articles/Infoservice/Newsletter: None
In the MDC system parameters, an FPU PRESS XDCR SIGNAL showing 3740 PSI indicates the FCU have detected a malfunction in the system and do not send the excitation signal to the FPU pressure transducer.
MDC REPORT: SYSTEM PARAMETERS
FILENAME:
DATE:
...
FLAP SURFACE ANGLE - 3.74 DEG
FPU PRESS XDCR SIGNAL - 3740 PSI
APU HOURS - 1116.75 HRS
…
Source of the problem still has to be found.
Quick Links:
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Operational Test of the Flap Control Unit (FCU) | AMM 27-51-05-710-801 |
| Electrical Rigging of the Flap System | AMM 27-52-00-820-801 |
| Mechanical Rigging of the Flap System | AMM 27-52-00-820-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers.
- If system checks are good, do close out.
- If fault remains, continue with next step.
FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - Perform a General Visual Inspection of the Flap system per AMM (Verify integrity of driveline by pulling and pushing on the flap panel and by attempting to rotate the driveline by hand, verify integrity of AGB, and actuators to ensure that they are not loose or do not have stripped gears.).
- Replace any defective component per AMM.
- Continue with next step.
- Reset the FCU by pressing the FCU reset button on the MAINTENANCE TEST control-panel. If unable to reset, engage the Alternate Flaps button with the left hydraulic system pressurized, and attempt another reset using the Flap Reset switch on the left galley.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Verify wiring to the position sensors. Check for any shorts or opens in the wiring/shielding. Where accessible, shake the wiring and ensure no fluctuation in supply voltage of 7 volts. Check the flap position sensor for possible internal failures.
LH Channel A LH Channel B A124AP1 MPE77P1 Value A124BP1 MPE77P2 Value 8F, 8E 1, 2 110Ω 14K, 15K 1, 2 110Ω 10F, 10E 3, 4 75Ω 14H, 15H 3, 4 75Ω 9F, 9E 5, 6 75Ω 14J, 15J 5, 6 75Ω RH Channel A RH Channel B A124BP1 MPE78P1 Value A124AP1 MPE78P2 Value 9F, 9E 1, 2 110Ω 14K, 15K 1, 2 110Ω 11F, 11E 3, 4 75Ω 14H, 15H 3, 4 75Ω 10F, 10E 5, 6 75Ω 14J, 15J 5, 6 75Ω - Carry out mechanical rigging of the flap system per AMM.
- Continue with next step.
- Carry out electrical rigging of the flap system per AMM.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replaced FCU per AMM.
- If system checks are good, do close out.