02/26/21
Message Overview:
Message Description:
R-GP-5 input to IRS 2 is inactive, while R-GP-5 input to IRS 1 is reported active.
Possible Causes:
- Inertial Reference Unit (IRU) 2 (A232)
- Junction Box 4 (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Operational Test of the Inertial Reference System (IRS) | AMM 34-45-00-710-801 |
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset IRU 2 (CB2-C2) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap IRUs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus R-GP-5 from IRU 2 connector A232P1 to Junction Box #4. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace Junction Box #4.
- Do close out.