03/01/21
Message Overview:
Message Description:
No ARINC R-GP-5 data received at Left Spoiler Electronic Control Unit (SECU 1) while the Data Concentrator Unit Ch. B (DCU) is not reporting ARINC R-GP-5 databus failure.
Possible Causes:
- Spoiler Electronic Control Unit 1 (SECU 1) (A118)
- Junction Box 4 (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0037 - Spoiler Electronic Control Unit (SECU) - Circuit Breaker Reset Procedure (20501 - 20999)
- AW300-27-0081 - Spoiler Electronic Control Unit (SECU) and Horizontal Stabilizer Electronic Control Unit (HSTECU) - Cold Temperature Circuit Breaker Reset Procedure (20501 - 20999)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-63-13-000-802 |
| Installation of the Junction Box JB4 | AMM 24-63-13-400-802 |
| Functional Test of Junction Box JB4 | AMM 24-63-13-720-801 |
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Follow the circuit breakers reset procedure documented in AW300-27-0037.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Visually inspect SECU's and tray's connectors for damages. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- SwapSECUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: An Electronic Rigging of the SECUs is necessary after a swap or a SECU replacement.
- Do wiring checks of the ARINC R-GP-5 data bus between DCU connector A14EP1, Junction Box 4 tests points (TP 67 ARINC HI - TP 70 ARINC LO) and SECU 1 connector A118AP1 (both inputs: command and monitor). Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Junction Box 4.
- Do close out.