03/01/21
Message Overview:
Message Description:
No Cross Channel ARINC Input to Spoiler Electronic Control Unit 1 (SECU1).
Possible Causes:
- Spoiler Electronic-Control Unit 1 (SECU 1) (A118)
- Spoiler Electronic-Control Unit 2 (SECU 2) (A119)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0037 - Spoiler Electronic Control Unit (SECU) - Circuit Breaker Reset Procedure (20501 - 20999)
- AW300-27-0081 - Spoiler Electronic Control Unit (SECU) and Horizontal Stabilizer Electronic Control Unit (HSTECU) - Cold Temperature Circuit Breaker Reset Procedure (20501 - 20999)
Forum Articles/Infoservice/Newsletter: None
NOTE: If CAS messages SPOILERS FAULT (Caution), SPOILERS FAULT (Advisory) and STAB TRIM FAULT (Advisory) are all displayed at the same time on the EICAS momentarily for few seconds (between 3 to 20 seconds) and possibly MDC messages B3-007899 XTALK ARINC BUS [SPOILER ECU 1] or B3-007932 XTALK ARINC BUS [SPOILER ECU 2], B3-007882NO L-SECU-1 BUS TO DCU [SPOILER ECU 1], B3-007915NO R-SECU-1 BUS TO DCU [SPOILER ECU 2] and B3-007969 INVALID SECU INPUT [STALL COMPUTER] displayed together in the fault message history at the time of failure, download and send both SECU NVM files to the Bombardier Customer Response Center (CRC) for analysis.
Quick Links:
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Follow the circuit breakers reset procedure documented in AW300-27-0037.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks of the ARINC XLINK data bus between SECU 1 connector A118AP1 and SECU 2 connector A119AP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Visually inspect SECU's and tray's connectors for damages. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SECUs.
NOTE: An Electronic Rigging of the SECUs is necessary after a swap or a SECU replacement. - Do close out.