03/02/21
Message Overview:
Message Description:
The STALL DISENGAGE output signal from SPC A or SPC B is invalid or shorted to ground. Verify SPC and aircraft wiring.
Possible Causes:
- Stall Protection Computer (SPC) (A178)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Stall Protection System (SPS) | AMM 27-32-00-710-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the SPC circuit breakers 'SPC CH A' (CBP1-B10) and 'SPC CH B' (CBP2-10) and perform an SPC Pilot Activated Test (PAT).
- If system checks are good, do close out.
- If fault remains continue to next step.
- Re-rack SPC.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Do wiring check between SPC connector A178AP1 and Flight Guidance Panel connector PL9P1. Repair as required.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Do wiring check between SPC connector A178BP1 and Flight Guidance Panel connector PL9P2. Repair as required.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Replace SPC.
- Do close out.