Message Overview:
Message Description:
The RTL speed discrete output signals from SPC A are invalid.
Possible Causes:
- Stall Protection Computer (SPC) (A178)
- Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) (A130)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Stall Protection System (SPS) | AMM 27-32-00-710-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Removal of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-000-801 |
| Installation of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-400-801 |
| Operational Test of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers and perform the Pilot Activated Test (PAT) of the Stall Protection System on the Systems Test control-panel located on the center pedestal.
STALL L PWR CB1-B10 STALL R PWR CB2-B10 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of RTL speed discrete wires between SPC and HST ECU. Repair as required.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Re-rack SPC.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Replace SPC.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Re-rack HST ECU.
- If system checks are good, do close out.
- If fault remains continue to next step.
- Replace HST ECU.
- Do close out.