Message Overview:
Message Description:
Flap Control Unit (FCU) detected a over-speed condition in the LH or RH driveline. Check LH and RH wing Flap driveline for disconnect.
Possible Causes:
- Mechanical Failure in the Transmission System
- Left Flap Position Sensor (MPE77)
- Right Flap Position Sensor (MPE78)
- Flap Control Unit (FCU) (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0058 - Flap Control Unit - CAS Messages Reset procedure
Forum Articles/Infoservice/Newsletter: None
In the MDC system parameters, an FPU PRESS XDCR SIGNAL showing 3,740 psi indicates the FCU have detected a malfunction in the system and do not send the excitation signal to the FPU pressure transducer.
Quick Links:
| Removal of the FLAP Lever | AMM 27-51-01-000-801 |
| Installation of the FLAP Lever | AMM 27-51-01-400-801 |
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Operational Test of the Flap Control Unit (FCU) | AMM 27-51-05-710-801 |
| Electrical Rigging of the Flap System | AMM 27-52-00-820-801 |
| Removal of the Flap Position Sensor | AMM 27-52-17-000-802 |
| Installation of the Flap Position Sensor | AMM 27-52-17-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers.
FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Reset the FCU by pressing the FCU reset button on the MAINTENANCE TEST control panel. If unable to reset, engage the Alternate Flaps button with the left hydraulic system pressurized, and attempt another reset using the Flap Reset switch on the left galley.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Verify current faults or fault message history shows the FLAP OVERSPEED fault.
- FCU label 355 bit 11 set to 1 show LH Flap panel over-speed.
- FCU label 355 bit 12 set to 1 show RH Flap panel over-speed.
- Verify integrity of driveline by pulling and pushing on the flap panel and by attempting to rotate the driveline by hand.
- If system checks are good, do close out.
- If problem remain continue to next step.
- Perform a visual inspection of the flex shafts, AGB, hard shafts and actuators.
- Check for loose parts, stripped gears, etc. Replace defective parts per AMM.
- If problem remains, continue to next step.
- Access and disconnect the left and right position sensors. Visually inspect the connector and pins for signs of water ingress or any type of damage.
- If no damage or defect is found, continue with next step.
- If damage or defects are found, rectify as required.
- Perform a resistance check of both position sensors on both channels as follows:
LH Position Sensor Channel A
From To Expected Result Result MPE77P1-1 MPE77P1-2 110Ω MPE77P1-3 MPE77P1-4 75Ω MPE77P1-5 MPE77P1-6 75Ω MPE77P1-1 Ground Open MPE77P1-2 Ground Open MPE77P1-3 Ground Open MPE77P1-4 Ground Open MPE77P1-5 Ground Open MPE77P1-6 Ground Open LH Position Sensor Channel B
From To Expected Result Result MPE77P2-1 MPE77P2-2 110Ω MPE77P2-3 MPE77P2-4 75Ω MPE77P2-5 MPE77P2-6 75Ω MPE77P2-1 Ground Open MPE77P2-2 Ground Open MPE77P2-3 Ground Open MPE77P2-4 Ground Open MPE77P2-5 Ground Open MPE77P2-6 Ground Open RH Position Sensor Channel A
From To Expected Result Result MPE78P1-1 MPE78P1-2 110Ω MPE78P1-3 MPE78P1-4 75Ω MPE78P1-5 MPE78P1-6 75Ω MPE78P1-1 Ground Open MPE78P1-2 Ground Open MPE78P1-3 Ground Open MPE78P1-4 Ground Open MPE78P1-5 Ground Open MPE78P1-6 Ground Open RH Position Sensor Channel B
From To Expected Result Result MPE78P2-1 MPE78P2-2 110Ω MPE78P2-3 MPE78P2-4 75Ω MPE78P2-5 MPE78P2-6 75Ω MPE78P2-1 Ground Open MPE78P2-2 Ground Open MPE78P2-3 Ground Open MPE78P2-4 Ground Open MPE78P2-5 Ground Open MPE78P2-6 Ground Open - If all results are good as per tables above, continue with next step.
- If values are found out of range, replace defective position sensor and do close out.
- Perform a continuity check between the position sensors and the Flap Control Unit (FCU) as follows:
LH position sensor:
From To Result MPE77P1-1 A124AP1-8F MPE77P1-2 A124AP1-8E MPE77P1-3 A124AP1-10F MPE77P1-4 A124AP1-10E MPE77P1-5 A124AP1-9F MPE77P1-6 A124AP1-9E MPE77P2-1 A124BP1-14K MPE77P2-2 A124BP1-15K MPE77P2-3 A124BP1-14H MPE77P2-4 A124BP1-15H MPE77P2-5 A124BP1-14J MPE77P2-6 A124BP1-15J RH position sensor:
From To Result MPE78P1-1 A124BP1-9F MPE78P1-2 A124BP1-9E MPE78P1-3 A124BP1-11F MPE78P1-4 A124BP1-11E MPE78P1-5 A124BP1-10F MPE78P1-6 A124BP1-10E MPE78P2-1 A124AP1-14K MPE78P2-2 A124AP1-15K MPE78P2-3 A124AP1-14H MPE78P2-4 A124AP1-15H MPE78P2-5 A124AP1-14J MPE78P2-6 A124AP1-15J NOTE: Make sure there is no continuity to ground on each wire.
- If there is continuity, continue with next step.
- If there is no continuity, repair defective wiring as required and do close out.
- Replace FCU.
- If system checks are good, do close out.
- If problem remain continue to next step.
- Do close out.