Message Overview:
Message Description:
The LEFT ICE DETECTOR is detected failed by the Stall Protection Computer or the discrete wiring to the Stall Protection Computer is failed open circuit.
Possible Causes:
- Left Ice Detector (A65)
- Stall Protection Computer (SPC) (A178)
- Circuit Breaker
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| General Setup for Maintenance | |
|---|---|
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Maintenance Tasks | |
| Replacement of DC Circuit Breakers | AMM 24-65-00-960-801 |
| Operational Test of the Stall Protection System (SPS) | AMM 27-32-00-710-801 |
| Functional Test of the Stall Protection System | AMM 27-32-00-720-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Operational Test of the Ice Detection System | AMM 30-81-00-710-801 |
| Removal of the Ice Detector | AMM 30-81-01-000-801 |
| Installation of the Ice Detector | AMM 30-81-01-400-801 |
Troubleshooting Recommendations:
- Reset Left Ice Detector circuit breaker CB1-E7. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Check for presence of 28 VDC / Ground Returns at the Left Ice Detector (A65) as per the following table:
Measurement at Expected Results Results A65P1 - A 28 VDC A65P1 - G 28 VDC A65P1 - B Ground A65P1 - H Ground - If check is satisfactory, continue with next step.
- If check is not satisfactory, repair the defective wire or replace the defective circuit breaker.
- Do wiring check between Stall Protection Computer (A178) and Left Ice Detector (A65) for the following wires:
From To Results Conn. A178AP1 - 21 Conn. A65P1 - K - If wiring check is satisfactory, continue with next step.
- If wiring check is not satisfactory, repair the defective wire.
- Interchange the Left Ice Detector (A65) with the Right Ice Detector (A66). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Ice Detector.
- Replace the Stall Protection Computer (A178).
- Do close out.