Message Overview:
Message Description:
The WING CROSS VALVE is detected failed in open position.
Possible Causes:
- Wing Cross-Bleed Valve (MPE10)
- Anti-Ice Control Panel (PL19)
- Integrated Air System Controller 1 (IASC1) (A55)
- Integrated Air System Controller 2 (IASC2) (A56)
- Junction Box (JB1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Wing Cross-Bleed Valve | AMM 30-11-05-000-801 |
| Installation of the Wing Cross-Bleed Valve | AMM 30-11-05-400-801 |
| Removal of the Anti-Ice Control Panel | AMM 30-11-09-000-801 |
| Installation of the Anti-Ice Control Panel | AMM 30-11-09-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Verify XBleed Valve sense line is not obstructed internally, or damaged. Inspect fittings, and pass through for damage.
- Manually close the wing cross-bleed valve.
- Check for continuity on wing cross-bleed between MPE10J1 pin 4, pin 5.
- If there is continuity, go to step 5.
- If there is no continuity, continue with next step.
- Replace wing cross-bleed valve.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks between wing cross bleed valve and JB1. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks between JB1 and IASC1. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks between JB1 and IASC2. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the JB1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do close out.