Message Overview:
Message Description:
No A-DCU-6 data received at Lamp Driver Unit.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Lamp Driver Unit (LDU) (A52)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Removal of the Lamp Driver Unit | AMM 31-52-01-000-801 |
| Installation of the Lamp Driver Unit | AMM 31-52-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU A Circuit Breaker CB1-D1 and ANNUNCIATOR CTRL 1 Circuit Breaker CB1-D3. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between DCU (A14), and LDU (A52) for the following wires:
From To Result Conn A14FP1 - 7A Conn A52P1 - 75 (Note 1) Conn A14FP1 - 7B Conn A52P1 - 76 (Note 1) - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair wiring.
NOTE 1: For Aircraft 20001 - 20124 Post STC ST01732LA-D or Post SB 100-46-06, the LDU connectors are identified "A52BP1" and "A52BP2". - Replace DCU (A14). Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace LDU (A52).
- Do close out.