03/08/21
Message Overview:
Message Description:
No B-DCU data received at R-IOC AND 2-of (L-PFD, L-MFD, R-PFD, R-MFD, IASC1A, IASC1B, IASC2A, IASC2B, B-LDU, R-RIU).
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- EICAS DCU B Circuit Breaker (CB2-D1)
- Data Concentrator Unit (DCU) Cooling Fan (A194)
- Right Cockpit Circuit-Breaker Panel (RCBP) (CBP2)
- Junction Box 4 (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-63-13-000-802 |
| Installation of the Junction Box JB4 | AMM 24-63-13-400-802 |
| Replacement of DC Circuit Breakers | AMM 24-65-00-960-801 |
| Removal of the Cockpit Circuit-Breaker Panel (CCBP) | AMM 24-65-01-000-801 |
| Installation of the Cockpit Circuit-Breaker Panel (CCBP) | AMM 24-65-01-400-801 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Removal of the Data Concentrator Unit (DCU) Tray Fan | AMM 31-41-03-000-802 |
| Installation of the Data Concentrator Unit (DCU) Tray Fan | AMM 31-41-03-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU B Circuit Breaker CB2-D1. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Disconnect DCU Tray Fan (A194). Is the fault message still present?
- If NO, replace defective DCU Tray Fan.
- If YES, continue with next step.
- Confirm presence of the Ground at the DCU (A14).
Measurement at Expected Result Result Conn. A14CP1-2J Aircraft Ground (PWR GND) Conn. A14CP1-2K Aircraft Ground (PWR GND) Conn. A14CP1-7C Aircraft Ground (Chassis GND) Conn. A14CP1-7D Aircraft Ground (Chassis GND) Conn. A14CP1-7G Aircraft Ground (Chassis GND) Conn. A14CP1-7H Aircraft Ground (Chassis GND) - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair wiring.
- Confirm presence of the 28 VDC at the DCU (A14).
Measurement at Expected Result Result Conn. A14CP1-1J Aircraft Ground (PWR GND) Conn. A14CP1-1K Aircraft Ground (PWR GND) - If the check is satisfactory, continue with step 7.
- If the check is not satisfactory, continue with next step.
- Do wiring check between DCU (A14), right Circuit Breaker Panel (CBP2) and DCU Tray Fan (A194), through Junction Box 4, for the following wires:
From To Result Conn. A14CP1-1J CBP2J1-31 Conn. A14CP1-1K CBP2J1-31 Conn. A194P2-A CBP2J1-31 - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair defective wire or Junction Box 4.
- Replace EICAS DCU B Circuit Breaker CB2-D1. Is the fault message still present?
- If NO, do close out.
- If NO, replace defective Circuit Breaker Panel.
- Replace DCU (A14).
- Do close out.