Message Overview:
Message Description:
NO B-DCU-4 data received at IASC1-B and IASC2-B.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Integrated Air System Controller 1 (IASC) (A55)
- Integrated Air System Controller 2 (IASC) (A56)
- Junction Box 2 (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU B Circuit Breaker CB2-D1. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Remove IASC 1 (A55). Is the message B3-006924 (ATA21) present in MDC current fault?
- If YES, continue with next step.
- If NO, replace defective IASC 1.
- Re-install IASC 1 (A55).
- Remove IASC 2 (A56). Is the message B3-006906 (ATA 21) present in MDC current fault?
- If YES, continue with next step.
- If NO, replace defective IASC 2.
- Re-install IASC 2 (A56).
- Do wiring check between DCU (A14), IASC 1 (A55) and IASC 2 (A56), through Junction Box 2, for the following wires:
From To Result Conn A14EP1-10A Conn. A55P4-61 Conn A14EP1-10B Conn. A55P4-66 Conn A14EP1-10A Conn. A56P4-61 Conn A14EP1-10B Conn. A56P4-66 - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair wire or replace defective JB2.
- Replace DCU (A14).
- Do close out.