03/08/21
Message Overview:
Message Description:
B-DCU-8 bus data absent at R-RIU.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Radio Interface Unit 2 (RIU) (A18)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Radio Interface Unit (RIU) | AMM 23-51-21-000-801 |
| Installation of the Radio Interface Unit (RIU) | AMM 23-51-21-400-801 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU B Circuit Breaker CB2-D1, RIU 2A Circuit Breaker CB2-B4 and RIU/AURAL 2B Circuit Breaker CB2-B5. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between DCU (A14), and RUI 2 (A18) for the following wires:
From To Result Conn A14EP1-14A Conn A18P1-63 Conn A14EP1-14B Conn A18P1-64 - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair wiring.
- Replace DCU (A14). Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace RIU 2 (A18).
- Do close out.