Message Overview:
Message Description:
No RB-RIU-6 bus input at B-DCU, but data is present at R-MFD and R-CDU.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Junction Box 4 (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Radio Interface Unit (RIU) | AMM 23-51-21-000-801 |
| Installation of the Radio Interface Unit (RIU) | AMM 23-51-21-400-801 |
| Removal of the Junction Box JB4 | AMM 24-63-13-000-802 |
| Installation of the Junction Box JB4 | AMM 24-63-13-400-802 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU 2 Circuit Breaker CB2-D1. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between DCU (A14) and RIU 2 (A18), through Junction Box 4, for the following wires:
From To Result Conn. A14DP1-13A Conn. A18P2-31 Conn. A14DP1-13B Conn. A18P2-32 - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, repair defective wire or Junction Box 4.
- Replace DCU (A14).
- Do close out.