background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/10/21

Message Overview:

Message Name:

NO B-RDC-1 BUS OUTPUT

Message Code:

B3-007698

Associated CAS:

None

Reporting LRU: RDC A&B
System Description: 31-41-00
Schematic Diagram: 31-41-00
Wiring Diagram: 31-41-01
31-41-02
31-41-11
31-41-13

Message Description:

B-RDC-1 bus is reported inoperative by Data Concentrator Unit (DCU) channel A and B.

Possible Causes:

  • Remote Data Concentrator (RDC) (A13)
  • Data Concentrator Unit (DCU) (A14)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Data Concentrator Unit (DCU) AMM 31-41-01-000-802
Installation of the Data Concentrator Unit (DCU) AMM 31-41-01-400-802
Removal of the Remote Data Concentrator (RDC) AMM 31-41-05-000-802
Installation of the Remote Data Concentrator (RDC) AMM 31-41-05-400-802
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Reset EICAS RDC B Circuit Breaker CB2-D2, EICAS DCU A Circuit Breaker CB1-D1 and EICAS DCU B Circuit Breaker CB2-D1. Is the fault message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Do wiring check between RDC (A13) and DCU (A14) for the following wires:

    From To Result
    Conn. A13EP1-7A Conn. A14EP1-2C
    Conn. A13FP1-7B Conn. A14EP1-2D

    1. If the check is satisfactory, continue with next step.
    2. If the check is not satisfactory, repair defective wiring.

  3. Replace RDC (A13). Is the fault message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Replace DCU (A14).
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.