03/15/21
Message Overview:
Message Description:
Right GP-5 bus not communicating to Proximity Sensor Electronic Unit. Verify Proximity Sensor Electronic Unit, Input/Output Concentrator (IOC), and aircraft wiring.
Possible Causes:
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Input/Output Concentrator 2 (IOC 2) (A4-IOC2)
- Junction Box 4 (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Pull and reset the PSEU gear system breakers (CB1-C13, CB1-C14, CB2-C13, CB2-C14), recheck the system for the fault.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Reset the circuit breakers R IAPS CB CB2-B6, then look for other failures related to the Input Output Concentrators, swap the IOCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check the ARINC 429 data bus from the PSEU A9AP1 PINS 10G, 9G through Junction Box 4 to IAPS A4P101 PINS 1, 2. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check the ARINC 429 data bus from the PSEU A9AP1 PINS 10G, 9G through Junction Box 4 to DCU A14EP1 PINS 1A, 1B. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace JB4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Functional test the PSEU.
- Do close out.