03/15/21
Message Overview:
Message Description:
PSEU Discrete Output DOT03A, MLGWOW to Stall Protection Computer CH-A (A178) driver failed.
Possible Causes:
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Stall Protection Computer (SPC) (A178)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Pull and reset the PSEU gear system breakers (CB1-C13, CB1-C14), (CB2-C13, CB2-C14).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between Stall Computer A178AP1 pin 28 and PSEU A9CP1 pin 6C. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PSEU.
- Do close out.