Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/15/21

Message Overview:


Message Name:

MLGWOW CRVK40 DRV FAIL

Message Code:

B3-007627

Associated CAS:

PROX SYS FAULT
(Advisory)

Reporting LRU: PSEU LRU
System Description: 32-60-00
Schematic Diagram: 32-61-00
23-71-00
Wiring Diagram: 23-71-01
32-61-09
32-61-12



Message Description:

PSEU Discrete Output DOT08B, MLGWOW to Cockpit Voice Recorder Erase Enable Relay (K40) driver failed.

Possible Causes:

  • Proximity Sensor Electronic Unit (PSEU) (A9)
  • Cockpit Voice Recorder (CVR) Erase Enable Relay (K40)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

PSEU discrete block diagram

Quick Links:

Removal of the Proximity Sensor Electronic Unit (PSEU) AMM 32-61-09-000-801
Installation of the Proximity Sensor Electronic Unit (PSEU) AMM 32-61-09-400-801
Functional Test of the Proximity Sensor Electronic Unit (PSEU) AMM 32-61-09-720-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Wire Repair SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Pull and reset the PSEU gear system breakers (CB1-C13, CB1-C14), (CB2-C13, CB2-C14).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Do wiring check between WOW CVR ERASE ENABLE RELAY K40 (JB2-D64) JB2BP1 pin 26 and PSEU A9AP1 pin 2K. Repair as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Replace PSEU.