03/16/21
Message Overview:
Message Description:
The Right Inboard Brake Pressure Transducer fault detected by the Brake Control Unit.
Possible Causes:
- Right Brake Pressure Transducer (MT100)
- Brake Control Unit (BCU) (A67)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Brake Control Unit | AMM 32-43-01-000-801 |
| Installation of the Brake Control Unit | AMM 32-43-01-400-801 |
| Removal of the Brake Control Valve | AMM 32-43-09-000-801 |
| Installation of the Brake Control Valve | AMM 32-43-09-400-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Electrical Wiring - Continuity Test - Adjustment/Test | SPM 20-12-01-05 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Swap left and right inboard pressure transducers
- If problem follows, replace pressure transducer.
- If problem does not follow, go to next step.
- Verify wiring per the following table:
From (R IB PRESS XDCR) Pin To (BCU) Pin MT100P1 1 A67P2 67 MT100P1 2 A67P2 68 MT100P1 3 A67P2 57 MT100P1 4 A67P2 56 - Repair as required.
- If wiring is found serviceable, go to next step.
- Replace BCU.
- Do close out.