03/16/21
Message Overview:
Message Description:
The Right Outboard Brake Pressure Transducer fault detected by the Brake Control Unit.
Possible Causes:
- Right Outboard Brake Pressure Transducer (MT98)
- Brake Control Unit (BCU) (A67)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Brake Control Unit | AMM 32-43-01-000-801 |
| Installation of the Brake Control Unit | AMM 32-43-01-400-801 |
| Removal of the Brake Pressure Transducer | AMM 32-43-17-000-801 |
| Installation of the Brake Pressure Transducer | AMM 32-43-17-400-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Electrical Wiring-Continuity Test - Adjustment/Test | SPM 20-12-01-05 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Swap left and right outboard pressure transducers.
- If problem follows, replace pressure transducer.
- If problem does not follow, go to next step.
- Verify wiring per the following table:
From (R OB PRESS XDCR) Pin To (BCU) Pin MT98P1 1 A67P1 68 MT99P1 2 A67P1 67 MT99P1 3 A67P1 57 MT99P1 4 A67P1 56 - Repair as required.
- If wiring is found serviceable, go to next step.
- Replace BCU.
- Do close out.