Message Overview:
Message Description:
The BCU detects a discrepancy between the right hydraulic system pressure and the outboard brake pressure switch (S98).
Possible Causes:
- Brake Pressure Switch (RH) (S98)
- Brake Control Unit (BCU) (A67)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Brake Control Unit | AMM 32-43-01-000-801 |
| Installation of the Brake Control Unit | AMM 32-43-01-400-801 |
| Removal of the Brake Pressure Switch | AMM 32-43-45-000-801 |
| Installation of the Brake Pressure Switch | AMM 32-43-45-400-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Electrical Wiring-Continuity Test - Adjustment/Test | SPM 20-12-01-05 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset RCBP-C15 (INBD BRAKES).
- If the 'BRAKE FAULT' CAS message did not reappeared, do close out.
- If the 'BRAKE FAULT' CAS message still posted, continue with next step.
- Disconnect the outboard brakes pressure switch S98.
- Pressurize the Right Hydraulic system.
- Verifycontinuity between pins 2 and 3 of pressure switch S98.
- If there is continuity, replace pressure switch S98.
- If there is no continuity, continue with next step.
- Verifywiring for a short circuit per the following table:
From (PRESS SWITCH) Pin To (BCU) Pin S98P1 2 A67P1 40 S98P1 3 A67P1 43 - Repair as required.
- If wiring is found serviceable, replace BCU.