03/16/21
Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the L Dataload Relay - K159. Verify user interface, K159 and related wiring.
Possible Causes:
- Relay (K159)
- Junction Box JB1 Circuit-Card 1 (JB1-DB1)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Junction Box JB1 Circuit-Cards | AMM 24-63-01-000-803 |
| Installation of the Junction Box JB1 Circuit-Cards | AMM 24-63-01-400-803 |
| Operational Test of Junction Box JB1 Card 1 | AMM 24-63-01-710-805 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the JB1-DB1 connector JB1EP1 Pin 57 to the PSEU connector A9CP1 Pin 9B. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Circuit Board 1 of the Junction Box 1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.