Message Overview:
Message Description:
Proximity Sensor Electronic Unit Discrete Output DOT13B, MLGWOW to R Dataload Relay K158 driver failed.
Possible Causes:
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Pull and reset the PSEU gear system breakers (CB1-C13, CB1-C14, CB2-C13, CB2-C14), recheck the system for the fault.
- Check continuity of the aircraft wiring between the JB2-DB1 JB2EP1 PIN 60 to PSEU A9AP1 PIN 1G, the wire should be open to ground. With the PSEU installed, the JB2EP1 PIN 60 should be open for WOW.PSEU discrete block diagram.
- If possible, download and have field service review the PSEU NVM. Further troubleshooting will depend on results of the PSEU NVM.
- If the failure still exists with the wiring good, and the NVM download doesn't identify external inputs as the fault, replace the PSEU IAW.
- Functional check the proximity sensor electronic unit IAW AMM 32-61-09-720-801.