03/16/21
Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the RFWSOV Relay (K60).
Possible Causes:
- Relay (K60)
- Junction Box JB4 Circuit-Card 4 (JB4-DB4)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-63-13-000-803 |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-63-13-400-803 |
| Operational Test of Junction Box JB4 Card 4 | AMM 24-63-13-710-804 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Dowiring check from the JB4-DB4 connector JB4FP1 Pin 1A to the PSEU connector A9AP1 Pin 5K. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Circuit Board 4 of the Junction Box 4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.