Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the HDMG Relay - K170.
Possible Causes:
- Relay (K170)
- Right Secondary Power Center (SPC) (A38)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Put the Aircraft in a Weight-Off-Wheel Configuration with the Aircraft on the Ground | AMM 32-61-00-867-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Dowiring check from the Right Secondary Power Center connector A38P3 Pin 4 to the PSEU connector A9AP1 Pin 4G. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the relay K170.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.