Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/22/21

Message Overview:

Message Name:

INTERNAL FAULT

Message Code:

B3-006761

Associated CAS:

None

Reporting LRU: FMC 1
System Description: 34-61-00
Schematic Diagram: 34-61-00
Wiring Diagram: 31-45-01
34-61-03

Message Description:

An internal fault is detected with the L FMC.

Possible Causes:

  • Flight Management Computer 1 (FMC) (A4-FMC1)
  • Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-000-801
Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-400-801
Removal of the Flight Management Computer (FMC) AMM 34-61-01-000-801
Installation of the Flight Management Computer (FMC) AMM 34-61-01-400-801

Troubleshooting Recommendations:

  1. Reset L IAPS circuit breaker CB1-B6. Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, do close out.

  2. Swap FMC 1 with FMC 2. Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, do close out.

  3. Replace IAPS Card Cage (A4).
  4. Do close out.