03/22/21
Message Overview:
Message Description:
An internal fault is detected with the L FMC.
Possible Causes:
- Flight Management Computer 1 (FMC) (A4-FMC1)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
Troubleshooting Recommendations:
- Reset L IAPS circuit breaker CB1-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap FMC 1 with FMC 2. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace IAPS Card Cage (A4).
- Do close out.