Message Overview:
Message Description:
Right FMC buses are not received by 3 of the following LRU: R-IOC, L-PFD, L-MFD, L-FMC, R-PFD, R-MFD, while the Right IOC data is present.
Possible Causes:
- Flight Management Computer (FMC No. 2) (A4-FMC2)
- Integrated-Avionics Processor System (IAPS) Power Supply (PWR) No. 2 (A4-PWR2)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-34-0226 - FMC-6200 Lock up on Ground (20501 - 20999)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Integrated-Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-09-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset IAPS circuit breakers CB1-B6, CB2-B6 and CB1-E1. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
NOTE: Before you open the IAPS circuit breakers, make sure that all Engine FADEC circuit breakers are open. If the Engine FADEC circuit breakers remain closed, Engine Igniters will activate. This can cause injury to persons and damage to equipment.
- Swap FMC 2 with FMC 1. Is the fault message still present\?
- If YES, continue with next step.
- If NO, replace defective FMC.
- Swap IAPS PWR 2 with IAPS PWR 1. Is the fault message still present\?
- If YES, continue with next step.
- If NO, replace defective PWR.
- Replace IAPS Card Cage (A4).