Message Overview:
Message Description:
R-FMC-1 data is not received at R-IOC.
Possible Causes:
- Right Flight Management Computer (FMC 2) (A4-FMC2)
- Right Input/Output Concentrator Unit (IOC 2) (A4-IOC2)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Avionic Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated Avionic Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Integrated-Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-05-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Power Supply (PWR) | AMM 31-45-05-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset R IAPS circuit breakers CB2-B6. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Swap FMC 2 with FMC 1. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective FMC.
- Swap IOC 2 with IOC 1. Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective IOC.
- Replace IAPS Card Cage (A4).
- Do close out.