Message Overview:
Message Description:
R-IRS-2 inputs to MFD 2 and PFD 2 are inactive.
Possible Causes:
- Inertial Reference Unit (IRU) No. 2 (A232)
- Junction Box (JB4)
- Adaptive Flight-Display Unit MFD2 (A28)
- Adaptive Flight-Display Unit PFD2 (A26)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-63-13-000-802 |
| Installation of the Junction Box JB4 | AMM 24-63-13-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset IRU 2 (CB2-C2), PFD 2 (CB2-C3) and MFD 2 (CB2-C5) circuit breakers.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap IRUs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus R-IRS-2 from IRU 2 connector A232P1, through Junction Box 4, PFD 2 connector A26P2 and MFD 2 connector A28P2. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRUs connected to this data bus might cause this failure.
- Swap PFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap MFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace JB 4.
- Do close out.