03/31/21
Message Overview:
Message Description:
Left MFD has reported the CCP failed. This failure is likely to be the result of a stuck CCP button. Suspect the CCP has a stuck button, wiring from CCP to MFD, or another CCP related malfunction.
Possible Causes:
- Left Cursor Control Panel (CCP 1) (PL25)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Cursor Control Panel | AMM 31-61-09-000-801 |
| Installation of the Cursor Control Panel | AMM 31-61-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Replace Left Cursor Control Panel (CCP 1) (PL25).
- Verify fault is cleared.
- If YES, go to step 6.
- If NO, continue with step 5.
- Perform wiring checks and repairs.
- Verify fault cleared.
- Perform close out.