Message Overview:
Message Description:
The fan speed is below the expected value.
Possible Causes:
- Traffic Alert/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Unit Mounting Tray
- Traffic Alert/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Unit (A238)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit | AMM 34-43-03-000-801 |
| Installation of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit | AMM 34-43-03-400-801 |
| Removal of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit Mounting Tray | AMM 34-43-07-000-801 |
| Installation of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit Mounting Tray | AMM 34-43-07-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset TCAS/XPDR1 (CB1-A5) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Confirm presence of the 28 VDC and Ground at the TSS cooling fan connector A187P1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the wiring check between TSS connector A238BP1 and TSS cooling fan A187P1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the TSS Mounting Tray.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace TSS.
- Do close out.