background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/01/21

Message Overview:

Message Name:

NO R-IOC-4 BUS INPUT

Message Code:

B3-539893

Associated CAS:

None

Reporting LRU: SVC
System Description: 34-34-00
Schematic Diagram: 34-34-00
Wiring Diagram: 34-34-01

Message Description:

R-IOC-4 bus input to SVC is reported failed while it is not reported missing by both FMCs and Data Link.

Possible Causes:

  • Synthetic Vision Computer (SVC) (A230)
  • Configuration Connector (J2000)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/ Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

NOTE: A GPS signal input is required for the SVS image to show on the pilot and the copilot primary flight display (PFD).

Quick Links:

Removal of the Synthetic Vision Computer (SVC) AMM 34-34-01-000-801
Installation of the Synthetic Vision Computer (SVC) AMM 34-34-01-400-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Reset SVS (CB2-A7) circuit breaker.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Dowiring check of the ARINC 429 data bus R-IOC-4 from SVC connector A230AP1 to J2000 Config. Connector. Repair/replace as required.

    1. If system check passes, do close out.
    2. If fault remains, continue with next step.

  3. Do wiring check of the internal connection of J2000 Config. Connector.

    1. If system check passes, go to step 5.
    2. If fault remains, continue with next step.

  4. Replace J2000 Config. Connector.

    1. If system check passes, do close out.
    2. If fault remains, continue with next step.

  5. Replace SVC.

    1. If system check passes, do close out.
    2. If fault remains, continue with next step.

  6. Do close out.