04/01/21
Message Overview:
Message Description:
R-IOC-4 bus input to SVC is reported failed while it is not reported missing by both FMCs and Data Link.
Possible Causes:
- Synthetic Vision Computer (SVC) (A230)
- Configuration Connector (J2000)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/ Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: A GPS signal input is required for the SVS image to show on the pilot and the copilot primary flight display (PFD).
Quick Links:
| Removal of the Synthetic Vision Computer (SVC) | AMM 34-34-01-000-801 |
| Installation of the Synthetic Vision Computer (SVC) | AMM 34-34-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset SVS (CB2-A7) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Dowiring check of the ARINC 429 data bus R-IOC-4 from SVC connector A230AP1 to J2000 Config. Connector. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the internal connection of J2000 Config. Connector.
- If system check passes, go to step 5.
- If fault remains, continue with next step.
- Replace J2000 Config. Connector.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace SVC.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do close out.