04/01/21
Message Overview:
Message Description:
R-GPS-2 bus data absent at TAWS but data is present at the SVC.
Possible Causes:
- Terrain-Avoidance Warning System (TAWS) Computer (A34)
- Configuration Connector (J2000)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-000-801 |
| Installation of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-400-801 |
| Removal of the Global Positioning Receiver | AMM 34-55-01-000-801 |
| Installation of the Global Positioning Receiver | AMM 34-55-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset TAWS (CB2-A6) circuit breaker or push in the TAWS TEST/RESET Switch on the center pedestal.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do thewiring check of the ARINC 429 data bus R-GPS-2 from the TAWS computer connector A34AP1, through the J2000 connector, to the GPS 2 connector A24BP1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace the TAWS computer.
- Do close out.